      The Steel Network 250MW-24 Tested wall brace for loading, cantilevered partial wall Rated Knee Wall Load Bearing Brace by Midwall™. Value Replaces labor/coordination of placing embedded angle into floor system Guide holes for attachment of MidWall to the stud Only certified steel is used 3.625" and 6" Meets IBC criteria Section 1607.7.1 Test data for 2.5" depth MidWall is available Anchors are by others and rating is determined by what bolt you use. Bolt used is based on recommendation of your engineer that specifies the wall. See Load Table tab for reference.

      Use Midwall™ for Interior Half Walls -Design internal pressure. For Parapets & Ribbon Windows - Design and Wind Pressure.  For Handrails and Guards: 50 lb/fy applied in any direction at the top of wall, 200 lbs applied in any direction at any point at the top of wall.

      Product Name:

      MidWall™ Kneewall Steel Brace Kit.

      US Patent #8,387,321

      Distributer

      Western Fabricating LLC
      Kneewall.com
      Midwall™ is a product of The Steel Network
      17061 Alico Commerce Court, Suite 104
      Fort Myers, Florida 33967
      phone: (239) 405-7214
      email: sales@kneewall.com
      web: www.kneewall.com

      Product Description:

      Midwall™ is a tested alternative in partial wall assemblies, designed to support out-of-plane loading in cantilevered partial wall systems that are unsupported at the top track.

      The out-of-plane loads are transferred to the floor system through a 1/2" thick plate nested in the flanges of the member with two 3/8" diameter fasteners (or {one} 1.2" diameter fastener for 250MW) used for the connection.

      Midwall™ 24" is generally used in interior half walls of less than 48" in height. Attach Midwall to 54 mil stud with #12 screws through all pre-drilled guide holes. Other studs in wall are typical infill studs.

      Midwall™ 48" is used in interior half walls equal to or more than 48" in height. Use one Midwall 48" as a substitute for a stud at the specified spacing, or attach to a 54 mil stud with #12 screws through all pre-drilled guide holes.

      Simple Installation:

      Install Steel Wall Support Step 1
      Midwall Brace Kit Installation
      Midwall Installation Procedures
      Install Steel Wall Support Step 2
      Install Steel Wall Support Step 3

      Options:

      Available in two lengths, 24" and 48". Midwall™ may be used in place of standard framing members, or in conjunction with them to frame a wall:

      • 2-1/2" wall width x 24" height Rated
      • 2-1/2" wall width x 48" height Rated
      • 3-5/8" wall width x 24" height Rated
      • 3-5/8" wall width x 48" height Rated
      • 6" wall width x 24" height Rated
      • 6" wall width x 48" height Rated

      Design Information:

      Criteria

      • IBC2009
      • Refer to Section 1607.7.1
      • Applications:

      • Handrails and Guards
      • Interior Half Walls
      • Parapets
      • Ribbon Windows
      • Handrails and Guards

      • 50 lb/fy applied in any direction at the top of wall
      • 200 lbs applied in any direction at any point at the top of wall.
      • Parapets & Ribbon Windows

      • Design and Wind Pressure
      • Interior Half Walls

      • Design internal pressure
      • Material Composition:

        MidWall

      • ASTM A1003/A1003M Structural Grade 50 (340) Type H, ST50H (ST340H), 50ksi (340MPa) minimum yield strength, 65ksi (450MPa) minimum tensile strength, G90 (Z275) hot-dipped galvanized coating. Material Thickness = 118mil (10 gauge, 0.1242" design thickness) for 250MW and 362MW. Material Thickness = 97mil (12 gauge, 0.1017" design thickness) for 600 MW.
      • MidWall Plate

      • ASTM A36/A36M: 36ksi (250MPa) minimum yield strength, 58-80ksi (400-550MPa) tensile strength, ½" minimum thickness.

      Midwall options

      The top track spanning between Midwall members acts as a load distribution member capable of distributing localized loads to multiple MidWall members. It is recommended to design track in these applications. Refer to the diagram above for an example of the distribution of the point load, P, to adjacent MidWall supports. At the end of the wall, Midwall is required at adjacent stud spacings. Designed spacing begins after two adjacent end supports.

      Load Tables Load Rated Wall